I have a Island Bahama 52 S. Class spa I bought used. I keep

Customer Question

I have a Island Bahama 52 S. Class spa I bought used. I keep getting the FLO and FLC error. When I first hooked it up and finally got the air out of the circulation line it worked fine for about 2 weeks. At first I got the FLO error now I have the FLC error. It seems the circulation pump may not be pushing much water and it keeps bubbling....The pressure switch will not close as well. Can you help?
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Billy replied 1 year ago.

hello,

is filter clear?

is pump impeller in good condition?

does pump keep running?

Customer: replied 1 year ago.
I took the filter out there is no blockage. How do check the impeller? Yes. The small circulation pump runs continuous.
Expert:  Billy replied 1 year ago.

you would need to remove the pump housing where the wheel is...attached to pump motor