I was recently given a older model hot tub. The brand is

Customer Question

I was recently given a older model hot tub. The brand is Jacuzzi and the model # ***** ***** It has a Balboa Model DUH136CCAH circuit (?) board. I have tried to get the tub running, but the GFI breaker always seems to trip. I have had to set up a separate power line for it using a 20 AMP breaker and 12-2 underground wire. At this point I am in the testing stage and have not buried the wire. The tub will come on and run for a short period and then the GFI in the tubs plug will trip, at the same time the far right relay (? not sure what its called, there are an number of them on the circuit board) will open. I took the cover off the box that the circuit board is in. Can you help me trouble shoot. Is 12-2 a heavy enough wire?
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Billy replied 1 year ago.
Hello,
do you know what control box series you have in the unit?
Generally starts with F or H
Use reply please
Customer: replied 1 year ago.
Isn't this it?
Expert:  Billy replied 1 year ago.
Thank you!
You need a 30 amp breaker and 10 g wire.
It sounds like it is tripping when heater kicks on.
Customer: replied 1 year ago.
The guy that gave us the tub said it ran off a 20 amp breaker
Expert:  Billy replied 1 year ago.
I am only going off the specs for that system.
Did he also run 12 wire?
Customer: replied 1 year ago.
Not sure, I'll give the 30 amp and 10 wire a try and let u know
Expert:  Billy replied 1 year ago.
also check pumps and give them a manual spin to make sure all are free
Customer: replied 1 year ago.
I think they are when it was plugged in it ran long enough that the Jets were coming out
Expert:  Billy replied 1 year ago.
thank you....then the heater first coming on may be the draw...
Customer: replied 1 year ago.
I'll let you know soon as I do thanks for your help
Expert:  Billy replied 1 year ago.
Thank you.
just keep this on your end and disregard computer generated prompts.
Billy
Customer: replied 1 year ago.
k, one other thing. I heard a clicking in the box, when I took the cover and plugged it in the relay (?) on the lower right hand side tripped.
Expert:  Billy replied 1 year ago.
what is relay labeled on schematic?
Customer: replied 1 year ago.
Ill have to check and get back to you. The cover is back on and its already dark here.
Expert:  Billy replied 1 year ago.
just respond when you can..do not reply until ready