How JustAnswer Works:
  • Ask an Expert
    Experts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional Answer
    Via email, text message, or notification as you wait on our site.
    Ask follow up questions if you need to.
  • 100% Satisfaction Guarantee
    Rate the answer you receive.
Ask Billy Your Own Question
Billy
Billy, Technician
Category: Pool and Spa
Satisfied Customers: 22118
Experience:  Licensed in Hydronics and Boilers
12672042
Type Your Pool and Spa Question Here...
Billy is online now
A new question is answered every 9 seconds

I have a Rheem Pool Heater, model RHM-15-0165 010165 P-M407A-EN-X

Customer Question

I have a Rheem Pool Heater, model RHM-15-0165 010165 P-M407A-EN-X - installed about three years ago. Over the last twelve months, the heater will stop running after about an hour or so of operation, displaying an error code "31" and message related to a "fan lockout". If I turn the heater off at the front panel and back on again - it restarts and works fine. This happens about 50% of the time the heater is run and regardless if I'm heating the pool or spa.
Other equipment installed:
Pentair IC40 Salt Generator
Pentair IntelliPH Acid Feeder
Dell Ozone Ozonator
Pentair Easy Touch
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Billy replied 1 year ago.
If you have a meter record the amp draw of the fan as it runs..it likely raises in amps and eventually shuts down on thermal overload