How JustAnswer Works:
  • Ask an Expert
    Experts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional Answer
    Via email, text message, or notification as you wait on our site.
    Ask follow up questions if you need to.
  • 100% Satisfaction Guarantee
    Rate the answer you receive.
Ask Billy Your Own Question
Billy
Billy, Technician
Category: Pool and Spa
Satisfied Customers: 22115
Experience:  Licensed in Hydronics and Boilers
12672042
Type Your Pool and Spa Question Here...
Billy is online now
A new question is answered every 9 seconds

I've a new Hayward pump installation, 230 volts. The pump is

Customer Question

I've a new Hayward pump installation, 230 volts. The pump is surging, clicking then shuts down but doesn't kick the breaker.
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Billy replied 1 year ago.
hello,
can you tell me the exact voltage to the pump when this happens?...is pump spinning correct direction?
Customer: replied 1 year ago.
Thanks, ***** *****
Expert:  Billy replied 1 year ago.
for the archives..what was the issue?
Customer: replied 1 year ago.
Hi, I've twice responded that problem solved and appreciate your answer. The installer wired for 115 despite label on pump stating that it was rigged for 230. Thanks, ***** ***** let up now....
Expert:  Billy replied 1 year ago.
I apologize it is not my intent to press the issue.
I see only 1 response...at which point, as you would say, I let up.
All I wanted was what the final fix was for my library. That is it.
I am glad you have it resolved and I thank you for the result.
No need to respond! We are all set.
Disregard any computer generated messages..

Related Pool and Spa Questions