How JustAnswer Works:
  • Ask an Expert
    Experts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional Answer
    Via email, text message, or notification as you wait on our site.
    Ask follow up questions if you need to.
  • 100% Satisfaction Guarantee
    Rate the answer you receive.
Ask Machinc Your Own Question
Machinc
Machinc, General Contractor
Category: Pool and Spa
Satisfied Customers: 814
Experience:  Has written home improvement articles since 2008. Earned South Carolina Residential Builders License in 1991.
75209918
Type Your Pool and Spa Question Here...
Machinc is online now
A new question is answered every 9 seconds

I have a Pentair Easy Touch (Upgrade from original Compool).

Customer Question

I have a Pentair Easy Touch (Upgrade from original Compool). The IntelliChlor and the auxiliary pump have suddenly quit working. The other functions in my pool are working as they should and as scheduled. I have determined that no electricity is getting to the auxiliary pump motor. Wh have had storms in the area recently, I looked at fuses and they appear ok.
Any ideas?
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Machinc replied 1 year ago.
I will snswer your question monentarily
Expert:  Machinc replied 1 year ago.
Lightning storms can not only damage
The breaker it can also damage the wiring.l
If you are sure the breaker is good
and the proper voltage is leaving toward
The pump check the connections and any
places along the wire that looks damaged.
Usually near a ground source ( like touching a grounded copper pipe)
there might be a burned spot.
if the connections and the wire are good replace the breaker. Customer
Expert:  Machinc replied 1 year ago.
Note:
A damaged flow sensor in front of this pump
could also be the problem
Customer
Customer: replied 1 year ago.
I do not detect any current inside control box where pump wires connect. Could I have a mother board problem that only effects certain functions (i.e. aux. pump and chlorinator)?
Expert:  Machinc replied 1 year ago.
If you have current into the board
Then yes the board would be the problem.
Of course current would only be present
where you tested when the board is calling on the
pump to operate.
Customer
Expert:  Machinc replied 1 year ago.
Note:
Sometines as expensive as boards are
it is worth the ecpense of having a professional
replace the board.
Suppliers often will not warranty a board
that is not professionalky installed.
Customer

Related Pool and Spa Questions