How JustAnswer Works:
  • Ask an Expert
    Experts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional Answer
    Via email, text message, or notification as you wait on our site.
    Ask follow up questions if you need to.
  • 100% Satisfaction Guarantee
    Rate the answer you receive.
Ask poolguy810 Your Own Question
poolguy810
poolguy810, owner - pool and spa service company
Category: Pool and Spa
Satisfied Customers: 1671
Experience:  Servicing pools and all brands of spas for over 28 years.
32482502
Type Your Pool and Spa Question Here...
poolguy810 is online now
A new question is answered every 9 seconds

Hey PoolGuy,I have a Thermospas hot tub that continues to heat even th

Customer Question

Hey PoolGuy,
I have a Thermospas hot tub that continues to heat even though it's reached the set temp. Once it reaches the set temp, the heater light on the control panel goes out but it continues to heat until it hits the high limit temp, it then shuts down. I just replaced the temp sensor (not the high limit sensor) and it looks like I'm having the same issue. I set the temp to 80 and it's already hit 90 with the hour. Any ideas?
Submitted: 1 year ago.
Category: Pool and Spa
Expert:  Mike R. replied 1 year ago.
Hi, I'm Mike and I have 20+ years of experience in the plumbing field. I'll be glad to assist you today. What happens if you switch the sensors at the connectors? Do you get a different fault situation?