Ask Rick Your Own Question
Rick, Construction Supervisor
Category: Plumbing
Satisfied Customers: 19080
Experience:  Licensed Master plumber with 40+ yrs. experience.
Type Your Plumbing Question Here...
Rick is online now
A new question is answered every 9 seconds

We can't keep our hot water heater going we have replaced

Customer Question

We can't keep our hot water heater going we have replaced the thermo coupler and burner unit and it still won't stay lite.
Submitted: 7 months ago.
Category: Plumbing
Expert:  Rick replied 7 months ago.

What is the brand and model number of your unit?

Customer: replied 7 months ago.
Maytag HRN11250XL06A003127
Expert:  Rick replied 7 months ago.

Can you light the pilot but it goes out after you walk away?

Customer: replied 7 months ago.
L06A003127 is the sr#
Customer: replied 7 months ago.
Expert:  Rick replied 7 months ago.

Ok, this is usually caused by clogged air intake vents. When the vent is clogged the main burner causes turbulence when it shuts down putting out the pilot. This unit draws air in around the base which should have a filter/screen to keep dust/lint/debris from getting into the burner chamber but many plumbers didn't install them. So you can try vacuuming under/around the base. If that doesn't work then the burner has to be pulled and the opening under the burner needs to be vacuumed out. There are special vacuum adapter attachments avalable at a plumbing supply house for this purpose.