I have a contractor trying to fire my unit first time. Says

Customer Question

I have a contractor trying to fire my unit for the first time. Says vacuum switch keeps the unit from staying on. When he bypasses the switch it works perfectly but when he reinstall it kicks off. he tested the switch and that is working as well
It is a high efficiency Air Temp Hot air system, run off propane.
Submitted: 1 year ago.
Category: Plumbing
Expert:  Billy replied 1 year ago.

hello,

is this a furnace with a plastic vent pipe to outside? and is there a second pipe?

Customer: replied 1 year ago.
Expert:  Billy replied 1 year ago.

the unit has one pipe that blows air out (exhaust) and another that sucks air in..has the pipe that sucks air in been removed from furnace and then try to start?

Customer: replied 1 year ago.
Not sure
Expert:  Billy replied 1 year ago.

can we try that?

Customer: replied 1 year ago.
Give me some time. Ill get back to you.
Expert:  Billy replied 1 year ago.

no problem..just let me know.

also..remove the small rubber tube from the pressure switch...now the fitting on the furnace side..poke a nail or paperclip all the way through...also make sure no water left in furnace...a shop vac works well for that

Customer: replied 1 year ago.
I remove the small tube and actuated the The switch by sucking in on the tube a little bit it worked fine I've checked and the tube and they wok fine too ...
Expert:  Billy replied 1 year ago.

did you do any of the items I mentioned?

Customer: replied 1 year ago.
Remember im still at work. Relaying your messages to contractor
Expert:  Billy replied 1 year ago.

Sorry I did not know you were not there...I apologize.

Billy

Customer: replied 1 year ago.
can you call my plumber.Ill pay the extra $18
Customer: replied 1 year ago.
1518(###) ###-####
Expert:  Phil replied 1 year ago.

I am sending the $18 additional services offer.

Customer: replied 1 year ago.
Too late. Ill figure it out in the am
Expert:  Phil replied 1 year ago.

OK, good luck with it.