I have a AO Smith Powershot FPSH 50 260 water heater. It

Customer Question

I have a AO Smith Powershot FPSH 50 260 water heater.

It heats up and cools down on its own does not stay hot all the time. I can periodically turn the blower switch on and off but this does not always work. In the morning it wil be cold and can be hot at night?
Submitted: 3 years ago.
Category: Plumbing
Expert:  Hauserplb replied 3 years ago.
Chat Conversation Started
Hauserplb :

Hello

Hauserplb :

My first question is, what size is the vent piping, how long is it (need to be fairly exact) and how many elbows (90's and 45's)?

Customer :

2.5" PVC, 2 90's, 1 45 approx 140" of pipe

Customer :

it is running right now and seems to be venting fine

Customer :

the LED indicator also flashed 6 times repeatedly

Customer :

the manual has 9 options for check repair and 3 options to issue

Customer :

testing to make sure chat is still going

Expert:  Plumbing Pro replied 3 years ago.

Hi, and Welcome to Just Answer. My name isXXXXX will do my best to answer your question to the best of my professional ability.

its seems you haven't been giving a answer yet so let me get that for you , Is the fan or blower motor kicking on when the tank lights up? it should and if the exhaust fan is not blowing then the tank will shut down and go into safe mode. How old is the heater ?

Expert:  Plumbing Pro replied 3 years ago.
a bad thermostat could also cause this , if its getting a false reading then it will cause the heater to act up and not get hot when you need it then go cold.
Expert:  Plumbing Pro replied 3 years ago.

If the gas Orifice gets clogged up then this could also happen .

or the thermo coupling could also be bad and causing this problem.
Customer: replied 3 years ago.

the blower turns on.

 

Is there a way to test the many "or's"?

Expert:  Plumbing Pro replied 3 years ago.
well this is if you have multi volt meter, and you know a thing or 2, you said it flashes 6 times fast ? what did the manual say about that ? how old is the heater?
Expert:  Plumbing Pro replied 3 years ago.
140 feet is kind of a long run for the vent , but I've seen longer. If you don't know the year the tank was made it should be near the serial number.
Customer: replied 3 years ago.

I read the manual but figured I would try this site for better advice

7 years old

6 Flashes System Lockout.

1. Reversed polarity in 115 volt power supply.

2. Heater/burner not properly earth grounded, check pin

3 on wire harness plug (valve end) to burner

4 trials for ignition failed or 4 loses of flame tube for 115 volts, check ground path to burner.

occurred before set-point was reached.

3. Ground fault interruption (GFI) breaker causing

intermittent operation, try non-GFI outlet.

After 1 hour "soft" lockout, SmartValve control

4. Flame sense rod dirty or incorrectly positioned.

will initiate a new ignition sequence if the call

5. Vent system length exceeded, too many elbows,

for heat is still present. (SmartValve can cycle blocked exhaust/intake switch opens after light off.

this way indefinitely.)

6. Flame sense/HSI wiring condition/connections.

7. Low or no supply gas pressure.

8. Fluorescent lighting on same breaker as heater.

9. Damaged, defective, or incorrectly positioned HSI.

Expert:  Plumbing Pro replied 3 years ago.

well if your getting power to the board, and you are getting gas, and the fan is running you said, then it might be the thermo coupling or thermo stat, but could be the flow sensor as well, if the tank is taht old then its on its last couple of useful working life and thats why its acting up. If you call the manufacture service hot line they will be able to tell you what part it is by the number of flashing lights , they also will be able to send you a replacement part, or they might even say that the heater is in need of replacement. And last of all the circuit board it self could of taken a dive for the deep end and it could be just a electrical problem.

 

if you go here and fill this out they will contact you back.

 

www.hotwater.com/customer_support/

Customer: replied 3 years ago.
Relist: Answer quality.
I thought the last set of answers were generic and I already have the manual and know what it says. The answer did not seem knwledgeable to my specific problem.
Expert:  Plumbing Pro replied 3 years ago.
in person a professional could test the unit , but not over Internet, contacting the manufacture is you best bet its too many things that could be causing this and i gave you the list of what it could be.
Expert:  Todd replied 3 years ago.
Clean the flame senor, which is right next to the igniter. This is a rod about 1/8 diameter . Use a piece of steel wool to clean this rod.
Todd, Plumber
Category: Plumbing
Satisfied Customers: 368
Experience: Union Plumber 28 years of service work, and new homes.
Todd and 3 other Plumbing Specialists are ready to help you
Expert:  Plmqwk replied 3 years ago.

I will also agree that when these water heaters get older (7 yrs qualifies) they do start acting up. The components start being more sensitive to the conditions and error codes become an issue. Your venting distance is one that can be causing this.

 

However, you may also have a deteriorated dip tube. This tube is inside the heater on your cold side inlet and introduces the fresh cold water to the bottom of your tank for heating. Remember, heat rises, so when you tank a shower the hot water thats been heated exits the top and new water enters the bottom for heating, mixes with the already hot. If no cold water is introduced for say 1/2 hr. the tank has the opportunity to catch up to its SET temperature. Typically, in the A.M. the first thing we do is use the toilet, wash hands, maybe even brush our teeth. Now the cold water is really cold. turn on the shower, and without the dip tube, the cold water is right at the top of your tank and this is what you get for your morning shower.

JustAnswer in the News:

 
 
 
Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.
 
 
 

What Customers are Saying:

 
 
 
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
< Last | Next >
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
  • Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help. Mary C. Freshfield, Liverpool, UK
  • This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!! Alex Los Angeles, CA
  • Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult. GP Hesperia, CA
  • I couldn't be more satisfied! This is the site I will always come to when I need a second opinion. Justin Kernersville, NC
  • Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around. Esther Woodstock, NY
  • Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know. Robin Elkton, Maryland
 
 
 

Meet The Experts:

 
 
 
  • Marc

    Plumber

    Satisfied Customers:

    996
    Plumbing heating & home maintenance contractor
< Last | Next >
  • http://ww2.justanswer.com/uploads/VE/Veillplumb/2011-8-31_155028_IMG1104.64x64.JPG Marc's Avatar

    Marc

    Plumber

    Satisfied Customers:

    996
    Plumbing heating & home maintenance contractor
  • http://ww2.justanswer.com/uploads/plmqwk/2010-08-28_151844_profile_pic.jpg Plmqwk's Avatar

    Plmqwk

    Master Plumber

    Satisfied Customers:

    850
    20+ years in plumbing field. Licensed master plumber, commercial plumbing inspector
  • http://ww2.justanswer.com/uploads/JE/jerrymassie/2011-1-15_45937_1111055.64x64.JPG Jerry's Avatar

    Jerry

    Plumber

    Satisfied Customers:

    777
    over 20 years residential plumbing experience.
  • http://ww2.justanswer.com/uploads/PL/plumber171/2011-8-13_11445_plumber.500x500.64x64.jpg Mario's Avatar

    Mario

    Master Plumber

    Satisfied Customers:

    604
    Master Plumber, Fire Sprinkler, and Jobbing Spec.
  • http://ww2.justanswer.com/uploads/ABSBoss/2009-03-25_163017_2007-1031_046.jpg Bud's Avatar

    Bud

    Plumber

    Satisfied Customers:

    538
    22 Years Field Experience - 17 Years Business Ownership - Residential or Light Commercial
  • http://ww2.justanswer.com/uploads/TH/theplumber717/2011-11-24_34039_DSCF7012.64x64.JPG Theplumber717's Avatar

    Theplumber717

    Plumber, Hvac Tech

    Satisfied Customers:

    520
    Lic Plumbing contractor, 27/yrs res,com,repair,Universal HVAC Tech
  • http://ww2.justanswer.com/uploads/skibum0101/2008-12-16_015819_just_answer.jpg Rick Mather's Avatar

    Rick Mather

    Building Inspector

    Satisfied Customers:

    494
    Assistant Building Official, HVAC Tech