Thermo King MD200 start cold run mins and shut down.

Customer Question

Thermo King MD200 start cold run for 10 mins and shut down. Found f4o1 fuse blown. change fuse run fo 10 seconds. fuse blown
Submitted: 1 year ago.
Category: Medium and Heavy Trucks
Expert:  Wayne replied 1 year ago.
Hi I'm Wayne
I will help you with this
Thank you for asking for me
F401 fuse is for the
fuel pump and fuel solenoid
feel if the fuel pump is getting hot
next is remove wire from fuel solenoid, switch to on,
and tap that wire against the solenoid stud,
should be a very little spark
if big spark, replace it
If this helped you, Please rate my answer
If Not, Please USE REPLY BUTTON FOR MORE INFO