What causes a DPF high temp alarm during manual active reg

Customer Question

What causes a DPF high temp alarm during manual active regeneration?
Submitted: 1 year ago.
Category: Medium and Heavy Trucks
Customer: replied 1 year ago.
This is on a 2008 Peterbuilt with a 2007 ISX Cummins engine.
Expert:  cumminsdr replied 1 year ago.
Hello and welcome to Just Answer! I would be more than happy to assist you today.High temp is normal to advise not to park where combustion can occure What fault code are you getting along with this?
Customer: replied 1 year ago.
No fault codes, just display stating High Temp Alarm during regeneration.
Expert:  cumminsdr replied 1 year ago.
What is your engine serial number?
Expert:  cumminsdr replied 1 year ago.
What is the engine serial number too?
Customer: replied 1 year ago.
Engine # *****
Reference # *****
Customer: replied 1 year ago.
Cummins ISX
Expert:  cumminsdr replied 1 year ago.
Since there are no faults present there is not an issue AS Per Cummins the High Exhaust System Temperature (HEST) Lamp indicates Higher-than-normal exhaust temperatures may exist due to active DPF regeneration.Operator should make sure the exhaust pipe outlet is not directed at any surface or material that may become hazardous
Customer: replied 1 year ago.
OK, so if the system completes regeneration and there are no fault codes then we can ignore the high temp alarm.
Expert:  cumminsdr replied 1 year ago.
If there was a true high temp issue the Aftertreatment system would trip a fault code and you would NOT be able to perform a regen due to the system protecting it's self from damage until the fault was resolved.
Customer: replied 1 year ago.
Each time the system was still regenerating after the high temp alarm displayed. I forced stopped the regeneration's because I was scarred of damaging the DPF or DOC. I will try again and see if it either completes or gives a fault and shuts itself down.
Customer: replied 1 year ago.
Can I contact you again if I receive a fault code?
Expert:  cumminsdr replied 1 year ago.
Let the regen go till it completes If there is a issue you will get a fault code and it will automatically stop the regen to protect the system. It is the normal process. If you get a code i will be here to assist. A regen can take up to 2 1/2 hrs to complete
Expert:  cumminsdr replied 1 year ago.
Hello just following up. Do you need more assistance? Please don't forget to rate my service.
Expert:  cumminsdr replied 1 year ago.
Please don't forget to rate my service.