2002 Jeep Grand cherokee Limited blower motor stayed on drained

Customer Question

2002 Jeep Grand cherokee Limited blower motor stayed on drained the battery had to pull fuse for the blower to get it to stop yes it runs with the key off
Submitted: 1 year ago.
Category: Jeep
Expert:  Chris replied 1 year ago.
Hello, my name is***** you for allowing me to assist you! Is this an auto temp system?
Chris
Customer: replied 1 year ago.
Yes
Expert:  Chris replied 1 year ago.
Ok I thought so. The problem is the blower motor control module (resistor block). It has shorted internally and is keeping the blower motor on. The module is mounted to the right lower area of the HVAC housing near the motor and is easy to replace. Note: The connector's on these modules get overheated and melted. Inspect the connector and replace it if needed when you replace the module. The Jeep dealer can sell you a new connector.
I hope that this information helps,and please let me know if you need further assistance with this.
Chris
Expert:  Chris replied 1 year ago.
By the way, if you want the procedure on how to replace it, let me know.
Chris
Expert:  Chris replied 1 year ago.
Hello? Are you still here?