Have a Lull 42 foot lift. The controls are getting more delayed

 

Customer Question

Have a Lull 42 foot lift. The controls are getting more delayed as the machine gets extended use time. The boom control seems the first to start working once the machine warms up. Everything works when we start the machine. But latter, it might take several seconds for any control to work when lever is engaged.

 



Already Tried:
checked hydrolic fluid. was a little low, filled it up and acts the same way. the fork lever may not work at all until you engage the boom control and as soon as in states to respond you can get the forks to work normally.

Submitted: 344 days and 1 hours ago.
Category: Industrial Equipment
Value: $23
Status: CLOSED
Picture
Expert:  spankyjr1 replied 344 days ago.


spankyjr1 :

let me review be rite back

spankyjr1 :

from what you are saying it sounds as if your pump is week and on its way out these are the symptoms that happen works when cold as temp increases you have slow or no response there is no adjustment that you can make change pump and filter

spankyjr1 :

if you want you can hook up a high pressure gauge and check pressure at pump it should be about 2800psi use a gauge that goes to at least 5000psi be careful these high pressures can and will go through your skin and directly to your blood so be care full

Customer :
spankyjr1 :

did you have any other questions

 
Tweet

4 Mechanics are Online Right Now

Ask Your Question Now
Ask A Mechanic
Type Your Industrial Equipment Question Here...
characters left:

Top Industrial Equipment Experts

See More Mechanics

In The News

Nbc
Washington Post
New York Times
Cnn
Learn More

How It Works

  • Ask an Expert
  • Get a Professional Answer
  • Ask Followup Questions
  • 100% Satisfaction Guarantee
Learn More
close
Find Expert answers related to your question.
Sign up using email
We will never post anything without your permission.
Already have an account? Sign in

Ask a Mechanic

Get a Professional Answer. 100% Satisfaction Guaranteed.
195 Mechanics are Online Now
Type Your Industrial Equipment Question Here...
characters left:
Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. Posts are for general information, are not intended to substitute for informed professional advice (medical, legal, veterinary, financial, etc.), or to establish a professional-client relationship. The site and services are provided "as is" with no warranty or representations by JustAnswer regarding the qualifications of Experts. To see what credentials have been verified by a third-party service, please click on the "Verified" symbol in some Experts' profiles. JustAnswer is not intended or designed for EMERGENCY questions which should be directed immediately by telephone or in-person to qualified professionals.
Truste
Contact Us | Terms of Service | Privacy & Security | About Us | Our Network
© 2003-2013 JustAnswer LLC
  • Pearl.com
  • JustAnswer UK
  • JustAnswer Germany
  • JustAnswer Spanish
  • JustAnswer Japan