I have a Rheem 80 plus model Number RGDC-10NCBJR. The

Customer Question

I have a Rheem 80 plus model Number RGDC-10NCBJR. The exhaust blower will start but the system will not ignite
Submitted: 1 year ago.
Category: HVAC
Expert:  airheatman replied 1 year ago.

Does the furnace have a pilot that stays lit all the time or an electronic pilot?

Customer: replied 1 year ago.
electronic
Expert:  airheatman replied 1 year ago.

Does the igniter light?

Customer: replied 1 year ago.
no
Expert:  airheatman replied 1 year ago.

OK Rheem used a couple different types of igniters.Does yours light up an glow or spark (when working)?

See the 2 below:

Customer: replied 1 year ago.
It looks like the Rheem Spark Ignitor
Expert:  airheatman replied 1 year ago.

Ok sorry about all the questions, but necessary for me to provide guidance for your specific furnace. Next look on ignition control and tell me which of the following controls your furnace has.

Customer: replied 1 year ago.
Robertshaw sp715A
Expert:  airheatman replied 1 year ago.

Let's start by cleaning the spark igniter wires with emory cloth or fine sandcloth and checking the wire to igniter and make sure it has no breaks and is making good connection.We will go from there.

Customer: replied 1 year ago.
the ignitor works and I see that the pilot lights. But know the gas regulator is pulsing (it clicks and allows some gas to come through then it clicks off).
Expert:  airheatman replied 1 year ago.

OK next step is to see if the 24volts is cutting out TR and TH on control or from board to valve.

Customer: replied 1 year ago.
Ok with the volt meter what are my contacts
Customer: replied 1 year ago.
how do I begin the test
Expert:  airheatman replied 1 year ago.

We want to make sure we are keeping 24 volts between TH and TR on control