New rheem combo pack wont turn on. I have a 240 volt supply

Customer Question

new rheem combo pack wont turn on. I have a 240 volt supply and it needs 208 volts. what do i do?
Submitted: 1 year ago.
Category: HVAC
Customer: replied 1 year ago.
(Posted by JustAnswer at customer's request) Hello. I would like to request the following Expert Service(s) from you: Live Phone Call. Let me know if you need more information, or send me the service offer(s) so we can proceed.
Expert:  BillyHvac replied 1 year ago.
power you have will work...it is the low voltage that turns the unit.
How is thermostat wired?
use reply
Customer: replied 1 year ago.
(Posted by JustAnswer at customer's request) Hello. I would like to request the following Expert Service(s) from you: Live Phone Call. Let me know if you need more information, or send me the service offer(s) so we can proceed.
Customer: replied 1 year ago.
can you give me a call at(###) ###-####im not getting any voltage at my thermostat.
Expert:  BillyHvac replied 1 year ago.
at the transformer just flip black and blue on the input side...
at the unit..do you have 24v at terminal R to C?
Customer: replied 1 year ago.
No I do not have any low voltage at the unit
Expert:  BillyHvac replied 1 year ago.
Thank you.
did you swap the black and blue wire?