Any idea why my Reznor heater wont fire? It turns "on", but

Resolved Question:

Any idea why my Reznor heater won't fire? It turns "on", but the burners don't fire and the fan doesn't kick on? It's two years old. The unit is not receiving fuel? I have triple checked valves.
Thanks for any help,
Ryan
Submitted: 2 years ago.
Category: HVAC
Expert:  Charles replied 2 years ago.

Hello, and thanks for your question ! My name is XXXXX XXXXX X am happy to assist you today!!

Are you sure its not getting fuel? is you unit pushbutton start or electronic start?

Customer: replied 2 years ago.

Hi Charles, the unit is electronic. I don't hear the click, click, click either?

Expert:  Charles replied 2 years ago.

Ok, it sounds like you have no power to the unit. You say it say on? is the ignitor battery or electric??

Customer: replied 2 years ago.
It's electric. The unit physically turns on when I turn the thermostat on and increase the temp, but it simply sits and hummmmms....
Expert:  Charles replied 2 years ago.

It sounds like the gas valve is not opening. I would double check the valveand make sure all the valves are lined up with the pipes.

Is this how they are??

Customer: replied 2 years ago.
Yes, two valves involved and both are in-line. Is there any way moisture in the "T" just before the regulator is the problem?
Expert:  Charles replied 2 years ago.
Only if it plugged up the line. Has there been a problem with that before? Is this natural or Lp gas?
Customer: replied 2 years ago.

No problem with that before, just threw it out there as a possibility? Natural gas. How about a faulty thermostat. When I turn up the thermostat and then go over to the unit the green light blinks steadily on the inside panel, FYI.

Expert:  Charles replied 2 years ago.
That was my next idea. This should be a basic Tstat. Is it digital??Can you pop the cover off the Tstat??
Customer: replied 2 years ago.
Yes, basic digital tstat. Cover is popped off...
Expert:  Charles replied 2 years ago.
How many wires? what colors?
Customer: replied 2 years ago.
2 wires, red into RH and white into W
Expert:  Charles replied 2 years ago.

Ok, remember where those wires go and remove them, Then touch them together, If the Tstat is bad then the heater will start. If it still will not start then the Tstat is ok. If its good then put the wires bac where they go and cloce up the Tstat,

Let me know what happens.

 

Charles

Customer: replied 2 years ago.
Alright, I'll be right back. FYI, I have had this heater for two years and it's been just fine. Standby...
Expert:  Charles replied 2 years ago.

Ok

Customer: replied 2 years ago.
Same as before, just the exhaust fan starts when the two wires are touched.
Expert:  Charles replied 2 years ago.
When you connected the wires did the igniter make any noise?
Customer: replied 2 years ago.
No noise. Just the exhaust fan.
Expert:  Charles replied 2 years ago.

And you did not get the fan with the Tstat correct??

 

Customer: replied 2 years ago.

No, I did get the fan with the tstat. No difference between tstat and touching the two wires together.

Expert:  Charles replied 2 years ago.

ok, its taken us a while to get here but I feel I have it narrowed down for you.

Either the igniter is bad.

Or the control board is bad. i would say that you should check the control board. If it is not communicating with the rest of the system then it will not allow the igniter to spark.

 

Give this a try. Check the board, there should be a light that will flash a code if there is a problem with it.

 

Customer: replied 2 years ago.
I get 2 green flashes and on the back of the panel it tells me "pressure switch does not close within 30 seconds of venter energized"
Expert:  Charles replied 2 years ago.

Ok, thats your problem. the preasure switch is bad,

thats why I wanted you to check the board, the board will tell you if there is a failure.

if you decide to change out the switch yourself let me know how it goes.

I hope this helps answer your question and solve the issue.

If so please click the green accept button, if not im still here to assist you.

Thanks again,

Charles

 

Charles, Engineering contractor
Category: HVAC
Satisfied Customers: 2060
Experience: 20+ years in the construction industry
Charles and other HVAC Specialists are ready to help you
Customer: replied 2 years ago.

Don't worry, I'll definitely click the pay button. You have any suggestions on where to buy Reznor parts? I imagine their website eh??

 

Thanks for your time Charles!

 

Ryan

Expert:  Charles replied 2 years ago.

No problem, its been fun working with you on this. I like things that make me think! it gets old fixing the same old issues all the time!! lol

this one actually made me think allot!

www.rezspec.com/catalog-udbp.html

Thats the easiest way, that way you know its the right part also.

I attached a link to the website for you.

 

Charles

JustAnswer in the News:

 
 
 
Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.
 
 
 

What Customers are Saying:

 
 
 
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
< Last | Next >
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
  • Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help. Mary C. Freshfield, Liverpool, UK
  • This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!! Alex Los Angeles, CA
  • Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult. GP Hesperia, CA
  • I couldn't be more satisfied! This is the site I will always come to when I need a second opinion. Justin Kernersville, NC
  • Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around. Esther Woodstock, NY
  • Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know. Robin Elkton, Maryland
 
 
 

Meet The Experts:

 
 
 
  • gotoman for ac's Avatar

    gotoman for ac

    HVAC Technician

    Satisfied Customers:

    4657
    51 years of experience install design and repair of all makes and models of AC
< Last | Next >
  • http://ww2.justanswer.com/uploads/SE/ServiceTechRus/2012-6-7_2119_056.64x64.JPG gotoman for ac's Avatar

    gotoman for ac

    HVAC Technician

    Satisfied Customers:

    4657
    51 years of experience install design and repair of all makes and models of AC
  • http://ww2.justanswer.com/uploads/AL/alumalite/2012-5-10_234018_shutterstock506249951forJA500.64x64.jpg Phil's Avatar

    Phil

    Mechanical Engineer

    Satisfied Customers:

    3888
    Retired HVAC/ Electrical & Boiler contractor. Industrial
  • http://ww2.justanswer.com/uploads/skibum0101/2008-12-16_015819_just_answer.jpg Rick Mather's Avatar

    Rick Mather

    HVAC Technician

    Satisfied Customers:

    3132
    35 years experience, HVAC
  • http://ww2.justanswer.com/uploads/RY/Rygis20/2011-5-7_3143_DSC5324.64x64.JPG Matthew's Avatar

    Matthew

    HVAC Technician

    Satisfied Customers:

    1994
    14 years experience in the HVAC field of service, installation, Manual J & D calculations
  • http://ww2.justanswer.com/uploads/KE/kentguidry/2011-9-26_214316_0059.64x64.jpg Kenton Guidry's Avatar

    Kenton Guidry

    HVAC Technician

    Satisfied Customers:

    962
    12 years install/service experience.
  • http://ww2.justanswer.com/uploads/solarman1947/2009-12-13_223915_phpkKBcXq_c2PM.jpg Rick Ridley's Avatar

    Rick Ridley

    UK Heating Engineer

    Satisfied Customers:

    871
    Retired But have had 30 years on the tools, Ex CORGI
  • http://ww2.justanswer.com/uploads/Ironheadfan/2009-12-18_222416_pump_005.jpg Tom's Avatar

    Tom

    HVAC Technician

    Satisfied Customers:

    770
    16+yrs HVAC/R service. Residential Commerical Industrial