Recent Feedback
i have a ruud heat pump and air handler [new] the wiring are brn wht/blue wht/blk g y the outside unit has y pur brn blue stat has r b y c g w need help w/correct wiring
Optional Information: Make : ruud heat pump 2 tonModel : hla-hm2417a Already Tried: stat wiring to ah=r-r,y-y,g-g;blk/wht-wht,wht/blue-brn both in and outside units run but no heat
connect browns together outdoor to indoor then to c on stat connect red to stat connect green at a/h to stat connect black-white and blue-white at a/h to white leading to outdoor and stat connect white to w1 on stat and connect white outside to purple connect athe orange stat wire to blue on outdoor unit connect oranges together at a/h,orange goes direct from blue outside to b terminal on stat also connect yellows togeter at a/h and connect to y at statMike40202.6535958681
Experience: 20 years experience with installation and service of residential/ light commercial HVAC equipment.