have a coleman furnace... 3 years old green light flashes 3

Customer Question

have a coleman furnace... 3 years old green light flashes 3 times furnace will not light. says combustion air switch fails to close. can i repair this myself or do i have to have a repairman? thanks ed
Submitted: 7 years ago.
Category: HVAC
Expert:  Rick Mather replied 7 years ago.
There is a little pie like device that has small rubber tubing from that switch to the flue remove rubber hose and clean both hose and the barbed fittings then try it
Customer: replied 7 years ago.
we tried that and the heater still would not light.. also for fyi we had our electric breakers off day before yesterday fixing a plug in receptical.. put in a gfi at that plug. after that the heater would not ignite. ...sorry to get back to you so late.... out all day.
Expert:  Rick Mather replied 7 years ago.
Whats on that furnace does anthing cycle or try to start
Rick Mather and other HVAC Specialists are ready to help you
Customer: replied 7 years ago.
yes...tries but burner will not light ... after about a minute it goes off and green light changes from steady green to 3 flashes...
Expert:  Rick Mather replied 7 years ago.

try cleaning the flame sensor with scotch brite or fine steel wool

Rick Mather and other HVAC Specialists are ready to help you
Customer: replied 7 years ago.
where would this senser be ... what do to get to the senser... is it by the rubber tubes or down by the gas burner area.
Expert:  Rick Mather replied 7 years ago.
It would be where the pilot light is and senses flame so the main gas flow can open
Expert:  Rick Mather replied 7 years ago.
Do not keep hitting the accept button they charge you every time you do that
Customer: replied 7 years ago.
thank you for the information on the accept button. will try to get to the heater later today. we are managers at a mobile home park and have office hours until 12 but today have a lein sale so will not finish until this afternoon.... will get back to you as soon as i can get a few minutes...
Expert:  Rick Mather replied 7 years ago.
Ok thank you