NEED WIRING DIAGRAM OF A GOODMAN FURNACE , model # ARUF-364216AA

Resolved Question:

NEED WIRING DIAGRAM OF A GOODMAN FURNACE , model # XXXXX
" WILL NOT KICK OFF " have changed the (thermostat board with 3 amp fuse),24 volt drop down transformer, wall thermmostat, think i have a wire crossed !
Submitted: 4 years ago.
Category: HVAC
Expert:  Billy replied 4 years ago.
Billy, HVAC Technician
Category: HVAC
Satisfied Customers: 19706
Experience: Endorsed for unlimited heating, cooling, oil burners, boilers, refrigeration, hydronics
Billy and 2 other HVAC Specialists are ready to help you
Customer: replied 4 years ago.
trouble started when elements would kick off but fan would stay on running slow , can not find the cause !
Customer: replied 4 years ago.

 

thanks for the diagram ! Danny !

Expert:  Billy replied 4 years ago.
You check sequencer?
Customer: replied 4 years ago.

is it shown on the diagram i purchased ?

where is it located ? " Sequencer"

Expert:  Billy replied 4 years ago.
Follow the themostat wires on the diagram into the unit terminals W
Customer: replied 4 years ago.
thank you so much i switched the seqencer to the one beside it and it kicks on and off with the thermosta the way it should now i know what to get THANKS AGAIN !
Expert:  Billy replied 4 years ago.
Good job.....well done
Customer: replied 4 years ago.

 

i contact the furnace place where i ordered the unit they mailed me the "sequencer" free of charge did not ask any questions it came today ! i have one question when i took the old sequencer out i did not watch where the purple "small purple" wire came off from

on the bottom of the sequencer it has two bladed male"big purple wire goes to element

dont know if small purle wire plugs on with it or big red wire ?

Expert:  Billy replied 4 years ago.
follow the purple wire back to to where it comes from and tell me what that point is
Customer: replied 4 years ago.

thermostat board "small purple wire "

 

big red wire L2 Breaker got them two mixed up !

Customer: replied 4 years ago.

 

 

p.s. how do i leave feedback for you ?

Expert:  Billy replied 4 years ago.
So you are all set now? Or still need the purple wire spot?
Customer: replied 4 years ago.
need to know for sure where the small purple wire plugs on the sequencer ? dont want to take any chances.
Customer: replied 4 years ago.

 

 

small purple wire goes from the EBTDR (NC ) down to the sequencer not for sure if it plugs on the right side or bottom left with the big purple wire , only two places to plug wires

Expert:  Billy replied 4 years ago.

 

i show that purple goes to 3 on the terminal board

Customer: replied 4 years ago.

yes but this diagram will not show a large purple wire from the sequencer to the element, thats whats got me mixed up ! thanks !Cry

Expert:  Billy replied 4 years ago.
you are welcome. I wish you well.
Customer: replied 4 years ago.
P.S. it sounds like a summer fan that runs all the time even after replaceing the sequencer , i have followed all the wires by the diagram thats in the furnace dont seem to be any wires crossed but there may be ! only when i take the big purple jumper wire from the sequencer with "red dot" on it and a # XXXXX off the element the fan stops, but then furnace starts working kicking on & off with thermostat like it should ! could there be something with that element or wiring ! Danny
Expert:  Billy replied 4 years ago.
If you have a G thermostat wire hooked up, remove it from terminal. Let me know if it stops
Customer: replied 4 years ago.

 

 

Removed "G" AND IT STILL RUNS

Expert:  Billy replied 4 years ago.
The only other possibility if G is removed is the ebtr board relay is stuck. Tap the board and see if it will release but that is the last optin of blower on all the time.
Customer: replied 4 years ago.

 

the only way it will stop running is to unplug the small purple wire from EBTR board ,whitch goes down to the sequencer with the white wire from the thermostat

this makes the THIRD new EBTR board that i have purchased for approx. 35.00 each

i can totally unhook all thermostat wires and it keeps running, i can unplug this one heating element and it runs the way it should but i only have three elements then ! it also has 3 speed fan !

JustAnswer in the News:

 
 
 
Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.
 
 
 

What Customers are Saying:

 
 
 
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
< Last | Next >
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
  • Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help. Mary C. Freshfield, Liverpool, UK
  • This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!! Alex Los Angeles, CA
  • Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult. GP Hesperia, CA
  • I couldn't be more satisfied! This is the site I will always come to when I need a second opinion. Justin Kernersville, NC
  • Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around. Esther Woodstock, NY
  • Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know. Robin Elkton, Maryland
 
 
 

Meet The Experts:

 
 
 
  • gotoman for ac

    HVAC Technician

    Satisfied Customers:

    4657
    51 years of experience install design and repair of all makes and models of AC
< Last | Next >
  • http://ww2.justanswer.com/uploads/SE/ServiceTechRus/2012-6-7_2119_056.64x64.JPG gotoman for ac's Avatar

    gotoman for ac

    HVAC Technician

    Satisfied Customers:

    4657
    51 years of experience install design and repair of all makes and models of AC
  • http://ww2.justanswer.com/uploads/AL/alumalite/2012-5-10_234018_shutterstock506249951forJA500.64x64.jpg Phil's Avatar

    Phil

    Mechanical Engineer

    Satisfied Customers:

    3888
    Retired HVAC/ Electrical & Boiler contractor. Industrial
  • http://ww2.justanswer.com/uploads/skibum0101/2008-12-16_015819_just_answer.jpg Rick Mather's Avatar

    Rick Mather

    HVAC Technician

    Satisfied Customers:

    3132
    35 years experience, HVAC
  • http://ww2.justanswer.com/uploads/RY/Rygis20/2011-5-7_3143_DSC5324.64x64.JPG Matthew's Avatar

    Matthew

    HVAC Technician

    Satisfied Customers:

    1994
    14 years experience in the HVAC field of service, installation, Manual J & D calculations
  • http://ww2.justanswer.com/uploads/KE/kentguidry/2011-9-26_214316_0059.64x64.jpg Kenton Guidry's Avatar

    Kenton Guidry

    HVAC Technician

    Satisfied Customers:

    962
    12 years install/service experience.
  • http://ww2.justanswer.com/uploads/solarman1947/2009-12-13_223915_phpkKBcXq_c2PM.jpg Rick Ridley's Avatar

    Rick Ridley

    UK Heating Engineer

    Satisfied Customers:

    871
    Retired But have had 30 years on the tools, Ex CORGI
  • http://ww2.justanswer.com/uploads/Ironheadfan/2009-12-18_222416_pump_005.jpg Tom's Avatar

    Tom

    HVAC Technician

    Satisfied Customers:

    770
    16+yrs HVAC/R service. Residential Commerical Industrial