I have a Trane Taystat 241 analog thermostat that I am replacing

Customer Question

I have a Trane Taystat 241 analog thermostat that I am replacing with a Honeywell TH 6110D. I also have a Honeywell RTH 7500D as a back-up. The Trane has R, B, G1, Y1, W1, W2. The Honeywell 6110D has G, W, C, Y R, Rc. Not sure what the RTH 7500D has since it is a back-up in case the 6110D is the wrong one.

Is the Trane that I have a 2 stage heat, 1 stage cool with NO heat pump? How do I connect the wires?
Submitted: 7 years ago.
Category: HVAC
Expert:  Kenton Guidry replied 7 years ago.
You typed Taystat, is that the correct name of your original thermostat?
Customer: replied 7 years ago.

TRANE TAYSTAT 241 is the old analog thermostat that I am replacing in my 9 year old home.

Expert:  Kenton Guidry replied 7 years ago.
I wanted to make sure it was not a Baystat.
Customer: replied 7 years ago.

It is a TRANE taystat

 

 

 

 

Expert:  Kenton Guidry replied 7 years ago.
Your going to have to use the 7500d.

Your r will now connect to r and rc on the new stat.

The g1 will now be g.

The w1 will go to the w1.

The w2 will go to the w2.

The y1 will connect to y.

B will connect to the c.

The
Customer: replied 7 years ago.
It looks like your last reply may have been incomplete as you ended with "The."
Expert:  Kenton Guidry replied 7 years ago.
The power to the furnace must be turned off when doing this.
Kenton Guidry and other HVAC Specialists are ready to help you
Customer: replied 7 years ago.
Got it! Thank you.
Expert:  Kenton Guidry replied 7 years ago.
You are very welcome.