old thermostat LUXPRO - wiring R - G - B - W2 - Y New

Customer Question

old thermostat = LUXPRO - wiring R - G - B - W2 - Y       New thermostat = Hunter 44665 - wiring Y1 - RH - RC1 - RC - Y/O - W/B - G. Have a single stage heat pump. Which wires go where on the Hunter thermostat? I tried RC1 = red wire, Y/O = yellow wire, W/B = blue wire, G = green wire, RH = white wire. It cooled all right; however, the return was blowing cold air out instead of pulling air out and condensate was leaking at the air handler.
Submitted: 5 years ago.
Category: HVAC
Expert:  Kenton Guidry replied 5 years ago.
So you do not have any back up heat sources?

The reason I ask is because of the w2 wire that your old thermostat used.
Customer: replied 5 years ago.
I have heat strips
Expert:  Kenton Guidry replied 5 years ago.
I am sorry to give you bad news but this thermostat will not operate your system properly.

Here is the text I just found in your manual that applies to your system.

"It will also operate single-stage heat pumps that do not have auxiliary or emergency heat."

Your unit has an auxiliary heat.
Expert:  Kenton Guidry replied 5 years ago.
Do you have any more questions or concerns that you would like to address?

Would you like to confirm the compatibility of a thermostat for your unit?
Expert:  Kenton Guidry replied 5 years ago.
If you want to stick with Hunter the 44860 supports multi stage heat pumps.
Customer: replied 5 years ago.
I am not sure I have heat strips in my unit. My unit is a RUUD Achiever High Efficiency Heat Pump. I looked thru the fan shroud and could not see any heat strips. How else can I tell if there are heat strips in my unit.
Expert:  Kenton Guidry replied 5 years ago.
Does your heat ever run and the outside condenser if off?
Customer: replied 5 years ago.
No, I don't think so - in fact I'm sure it doesn't.
Expert:  Kenton Guidry replied 5 years ago.
Well the old thermostat was not hooked up for a multi stage either.

Why did you think you had electric strips?

If you do have strips and they are mechanically good, you can hook up both stages.
Customer: replied 5 years ago.
In my first question, I stated it was a single stage heat pump. I don't know why I thought it had heat strips. I called my father-in-law who is a HVAC tech and he said I do not have heat strips.
Expert:  Kenton Guidry replied 5 years ago.
Make sure you turn your furnace breaker off before you do this.

Where did you hook up the wires on the old thermostat?

Your red wire will go to rc1 which is the same as rc. Then you will have to jump a wire over to rh.

Green will wire up to g.

The yellow wire will go to y1.



Customer: replied 5 years ago.
old thermostat - R = red, G = GREEN, B = BLUE, WZ = white, Y = yellow It was a five wire hook-up. So I need to know what to do with the blue and the white wires?
Expert:  Kenton Guidry replied 5 years ago.
What is the model of your old thermostat?
Customer: replied 5 years ago.
There are two numbers inside the old unit. 0301D and XXXXXXXXXXX I assume the model number is XXXXX LUXPRO.
Expert:  Kenton Guidry replied 5 years ago.
Are you for certain that both the w and b were hooked up on the old thermostat?

The reason I am asking is because b is for your heat pump and w2 is for a second stage heating.
Customer: replied 5 years ago.
Yes, I am absolutely sure. I wrote each wire color and letter on the thermostat down as I took the wire loose. If you can tell me how I can tell about the 2nd stage, I will try to find out. Also, there is a note inside the Hunter thermostat that states: 5-wire systems: Remove RC-RH jumper wire.
Expert:  Kenton Guidry replied 5 years ago.
Take the white wire off of rh.

You need a jumper from the rc to the rh.

Also the b from your old thermostat will go to your b on your new thermostat.

Please do this and leave the white wire off.

Lets see if that works.

I am going off of the hunter diagram that I found online for single stage heat pumps.
Expert:  Kenton Guidry replied 5 years ago.
Here is the manual I am using for reference in case you want it.

http://www.hunterfan.com/uploadedFiles/Support/Owner_Manuals/44008.pdf

Your diagram is on there on page 49.
Expert:  Kenton Guidry replied 5 years ago.
How did it work out?
Customer: replied 5 years ago.
The instructions on the inside front cover of the Hunter 44665 thermostat states clearly: 5-wire systems: remove RC-RH jumper wire. My thinking is the white wire is the reverse valve. If the instructions tell me not to jumper the RC-RH, why are you telling me to jumper them? I am not trying to be smart, just need to understand. Tell you what, I'm just going to call a local A/C company and get them to handle this. I just don't understand what you're telling me to do. Sorry.

JustAnswer in the News:

 
 
 
Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.
 
 
 

What Customers are Saying:

 
 
 
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
< Last | Next >
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
  • Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help. Mary C. Freshfield, Liverpool, UK
  • This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!! Alex Los Angeles, CA
  • Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult. GP Hesperia, CA
  • I couldn't be more satisfied! This is the site I will always come to when I need a second opinion. Justin Kernersville, NC
  • Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around. Esther Woodstock, NY
  • Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know. Robin Elkton, Maryland
 
 
 

Meet The Experts:

 
 
 
  • gotoman for ac

    HVAC Technician

    Satisfied Customers:

    4657
    51 years of experience install design and repair of all makes and models of AC
< Last | Next >
  • http://ww2.justanswer.com/uploads/SE/ServiceTechRus/2012-6-7_2119_056.64x64.JPG gotoman for ac's Avatar

    gotoman for ac

    HVAC Technician

    Satisfied Customers:

    4657
    51 years of experience install design and repair of all makes and models of AC
  • http://ww2.justanswer.com/uploads/AL/alumalite/2012-5-10_234018_shutterstock506249951forJA500.64x64.jpg Phil's Avatar

    Phil

    Mechanical Engineer

    Satisfied Customers:

    3888
    Retired HVAC/ Electrical & Boiler contractor. Industrial
  • http://ww2.justanswer.com/uploads/skibum0101/2008-12-16_015819_just_answer.jpg Rick Mather's Avatar

    Rick Mather

    HVAC Technician

    Satisfied Customers:

    3132
    35 years experience, HVAC
  • http://ww2.justanswer.com/uploads/RY/Rygis20/2011-5-7_3143_DSC5324.64x64.JPG Matthew's Avatar

    Matthew

    HVAC Technician

    Satisfied Customers:

    1994
    14 years experience in the HVAC field of service, installation, Manual J & D calculations
  • http://ww2.justanswer.com/uploads/KE/kentguidry/2011-9-26_214316_0059.64x64.jpg Kenton Guidry's Avatar

    Kenton Guidry

    HVAC Technician

    Satisfied Customers:

    962
    12 years install/service experience.
  • http://ww2.justanswer.com/uploads/solarman1947/2009-12-13_223915_phpkKBcXq_c2PM.jpg Rick Ridley's Avatar

    Rick Ridley

    UK Heating Engineer

    Satisfied Customers:

    871
    Retired But have had 30 years on the tools, Ex CORGI
  • http://ww2.justanswer.com/uploads/Ironheadfan/2009-12-18_222416_pump_005.jpg Tom's Avatar

    Tom

    HVAC Technician

    Satisfied Customers:

    770
    16+yrs HVAC/R service. Residential Commerical Industrial