Ask Honda-Man Your Own Question
Honda-Man
Honda-Man, Honda Mechanic
Category: Honda
Satisfied Customers: 2889
Experience:  I have an Associates Degree in Automotive. 10 Years experience on all makes and models. 20 Years Honda only including factory training. Over 30 years total.
75670266
Type Your Honda Question Here...
Honda-Man is online now
A new question is answered every 9 seconds

AC Blower wont blow. Fuses good. Blower & transistor

Customer Question

AC Blower wont blow. Fuses good. Blower & transistor replaced. worked briefly. new transistor passes volt & diode test. blower twitches when power applied via key.
Submitted: 1 year ago.
Category: Honda
Expert:  Honda-Man replied 1 year ago.

Welcome to JustAnswer.

Have you checked voltage at the blower motor? Can you please tell me what the voltage is? You might have a bad blower motor relay. Try switching the blower motor relay with the compressor clutch relay to see what happens. Also try unplugging the power transistor and grounding the green wire. The blower motor should come on. This will check the fuse, relay, and blower motor all at the same time. Please let me know what you find out.

Thanks, Honda-Man