Ranger: How to set the synchronizer when installing? Does the

Customer Question

How to set the synchronizer when installing? Does the vane need to be set in a particular position when dropping into position and respective of TDC?
Submitted: 2 years ago.
Category: Ford
Expert:  EricFromCT replied 2 years ago.
Yes, there is a special tool to install the synchronizer to make sure the sensor will be in the correct position. You can get the tool on amazon.
Expert:  EricFromCT replied 2 years ago.
I also have sent you can additional offer you can accept or decline. It is for the removal and installation instructions for the cam synchro on your truck in PDF format.
Customer: replied 2 years ago.
Eric
The camshaft synchronizer is the (older) model (ford PN F3T212K073A)that does NOT use the alignment tool. How do I set that when installing?
Expert:  EricFromCT replied 2 years ago.
do you have number 1 cylinder at tdc?
Expert:  EricFromCT replied 2 years ago.
You need to have cylinder 1 at tdc. Then align the CID sensor rotor with the trailing edge of the vane lined up with the short mark at the left hand side of the plastic window
Expert:  EricFromCT replied 2 years ago.
Then, install the assembled CID sensor and oil pump drive gear into the engine. As the assembly is pushed into place, the camshaft gear will rotate the sensor vane clockwise toward the center of the window.
Expert:  EricFromCT replied 2 years ago.
Then rotate the CID sensor counterclockwise. Install clamp and screw finger-tight. Rotate the sensor back to its position at right angles to the back of the block