Ask Glenn Your Own Question

Glenn
Glenn, Electrical Technician
Category: Electrical
Satisfied Customers: 2311
Experience:  over 30 years as a technician former journeyman electrician
281739
Type Your Electrical Question Here...
Glenn is online now
A new question is answered every 9 seconds

I am replacing My bathroom heater/vent fan/light.

Customer Question

I am replacing My bathroom heater/vent fan/light.
Submitted: 5 years ago.
Category: Electrical
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

Hello

What are you trying to do ?

Customer: replied 5 years ago.
Having a problem wiring the new unit.I have 3 seperat switches 1st turns on light above sink and light in heater/blower/light unit. I cannot get light to come on in new unit nor can i get heater to come on. reminder there are 3 seperat switches not a 3 way combo switch. Also there are 2 seperat black and white wires(1. b@k 2.b@k)entering unit in attic.Back to switches 2nd turns on blower 3rd turns on heater.Light above sink comes on.
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

How many wires do you have coming into the 3 switches ?

What color are they ?

Customer: replied 5 years ago.

2 wires black@white in each wire at least that is what it looks like without removing each switch

Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

Ok so a total of 6 wires ?

Customer: replied 5 years ago.
4wires Look like switches are looped toghter. My problem is this (i have heater working)but when i hook up the vent fan the light above the sink comes on real dim.Also i canot get the light in the new unit to come when iplug it in.
Expert:  Glenn replied 5 years ago.
Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

Do you have a meter for testing ?
Does the power come into the switch box ?
Customer: replied 5 years ago.
Power comes into switch box. I do not have a meter.
Expert:  Glenn replied 5 years ago.
Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

Ok the hot wire should pigtail to all 3 switches
All the white wires should tie together with a wire nut
Out of each switch the black to the fan/light /and heater will go
Customer: replied 5 years ago.
Remember there are 2 main wires coming from switch box each has a black and white wire in fan heater blower unit there is a blue and white wire for the light ablack and white wire for the fan and a red and white wire for the heater as of now the light comes on with the light above the sink the fan comes on correctly but when i have the lights on and then turnon the heater the heater works but the light in the unit cuts off light above sink stays on this does not bother me but i cannot figure out correct wiring.
Expert:  Glenn replied 5 years ago.
Hello

What i need to know is, Is there 2 wires coming from each device the fan the heater and the vanity light ?
Customer: replied 5 years ago.
Yes, heater(red@white)Fan(Black@White)Light(Blue@White)
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

Hello

All white wires will go to your incoming white wire

red from heater to heater switch

black from fan to fan switch

blue from light to the light switch

All switches will have the same incoming feed

Customer: replied 5 years ago.
One last statement I have two incoming WHITE WIRES and two incoming BLACK WIRES from attic.
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

By incoming do you mean they are power in ?

Customer: replied 5 years ago.
YES
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

Ok were the switches all jumped togeather before ? as far as the feed goes ?

Is there anything else not workng ?

How do you know these are hot without a meter ?

 

PLEASE answer all 3 questions

Customer: replied 5 years ago.

Switches already jumped together when home was built. Only thing wrong now is when you turn on heater the lights above sink and light in new BROAN model 655 comes on.I do not have a meter but the two wires in attic coming into BROAN unit have to be hot or nothing would work or is only one hot guess i need to get a meter.

Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

2 sets of wires going into the broan ?

Or just 2 wires ?

Customer: replied 5 years ago.
Two sets of wires . Each has a heavy duty white@Black.
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

Ok and I assume you must have them all hooked together

What I would do here is try one set first and see if it switches with the proper switch

If it dosen't swap them if that works just cap the 2 that must come from the heater because it comes on with the heater

Customer: replied 5 years ago.
OK I will try in the morning and get back with you. THANKS
Customer: replied 5 years ago.
Glenn I finally got it to work. The last thing i tryed with blind faith was to take the blue wire of the light socket in the broan and tie it to the one incoming white wire and then i tied the white wire of the light socket in the broan to the other incoming white wire. Blue to white and white to white. I do not understand but it worked.
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

sounds like it was some type of switch leg if it's 2 white wires what about the blacks ?

Glenn, Electrical Technician
Category: Electrical
Satisfied Customers: 2311
Experience: over 30 years as a technician former journeyman electrician
Glenn and 4 other Electrical Specialists are ready to help you
Customer: replied 5 years ago.
I tied the red wire of the heater to one incoming black and i tied the black wire of the vent fan to the other incoming black wire.
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

Great so your telling me there was no black wire coming into the broan ?

Customer: replied 5 years ago.
Glenn there were two black wires coming to the broan from the attic.
Expert:  Glenn replied 5 years ago.

Thank you for asking your question on graphic
You are corresponding with Glenn - Your personal online "Electrical Consultant"

 

What did you do with them ??

Customer: replied 5 years ago.
Glenn everthing is working correctly now thanks for all the help.
Expert:  Glenn replied 5 years ago.
your welcome

JustAnswer in the News:

 
 
 
Ask-a-doc Web sites: If you've got a quick question, you can try to get an answer from sites that say they have various specialists on hand to give quick answers... Justanswer.com.
JustAnswer.com...has seen a spike since October in legal questions from readers about layoffs, unemployment and severance.
Web sites like justanswer.com/legal
...leave nothing to chance.
Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent.
Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions.
I will tell you that...the things you have to go through to be an Expert are quite rigorous.
 
 
 

What Customers are Saying:

 
 
 
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
< Last | Next >
  • You did one super job of explaining to me everything there is to know about this fridge. I'm looking forward to asking you questions in the future. Jimmy Bagley, IA
  • Wonderful service, prompt, efficient, and accurate. Couldn't have asked for more. I cannot thank you enough for your help. Mary C. Freshfield, Liverpool, UK
  • This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!! Alex Los Angeles, CA
  • Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult. GP Hesperia, CA
  • I couldn't be more satisfied! This is the site I will always come to when I need a second opinion. Justin Kernersville, NC
  • Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around. Esther Woodstock, NY
  • Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know. Robin Elkton, Maryland
 
 
 

Meet The Experts:

 
 
 
  • Mike

    Master Electrician

    Satisfied Customers:

    1425
    Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer
< Last | Next >
  • http://ww2.justanswer.com/uploads/mikepettinato/2009-9-4_41145_DSC005132.jpg Mike's Avatar

    Mike

    Master Electrician

    Satisfied Customers:

    1425
    Licensed Master Electrician - OnQ Certified Data Voice Audio Video Installer
  • http://ww2.justanswer.com/uploads/WI/WireitUp/2012-6-17_18212_Photo00006.64x64.jpg Jason's Avatar

    Jason

    Service Technician

    Satisfied Customers:

    3278
    Over 15 years of experience in all types of installations, troubleshooting, and repairs.
  • http://ww2.justanswer.com/uploads/MI/MikeG2010/2012-6-7_192640_IMG01612.64x64.jpg Mike G.'s Avatar

    Mike G.

    Master Electrician

    Satisfied Customers:

    5318
    Proven Professional 45 years Experience
  • http://ww2.justanswer.com/uploads/AS/AssuredElectrical/2011-9-13_221243_me.64x64.gif AssuredElectrical's Avatar

    AssuredElectrical

    Master Electrician

    Satisfied Customers:

    2149
    Contractor-40 Years in the ElectricalTrade
  • http://ww2.justanswer.com/uploads/electrifier/2008-12-16_200429_headbob1.jpg electrifier's Avatar

    electrifier

    Master Electrician

    Satisfied Customers:

    1454
    Electrical contractor and electrical inspector for over 24 years with phone and networking expertise
  • http://ww2.justanswer.com/uploads/rich03dungo/2010-3-17_101556_tshirt2.jpg Rich's Avatar

    Rich

    Master Electrician

    Satisfied Customers:

    1115
    Over 35 years residential, commercial, industrial wiring, install, troubleshoot, service, maintain
  • http://ww2.justanswer.com/uploads/UR/urelectrician/2012-9-28_223652_JustAnswerPic.64x64.jpg Kevin's Avatar

    Kevin

    Licensed Electrician

    Satisfied Customers:

    993
    27 years as a Licensed Electrical Contractor in Illinois, 5 year college Electrical Instructor, Former Electrical Inspector, Diploma in Digital Electronics, Former Illinois Licensed Home Inspector