03 NEON 2.0L VINC- Crank no start - No Fire, No injector pulse.

Customer Question

03 NEON 2.0L VINC- Crank no start - No Fire, No injector pulse. Code 0685 ASD relay controll. Changed relay, changed ignition coil, and changed crank sensor. Checked wires to coil and fuse box seemed ok. Checked crank and cam sync with scanner. Have Cam and Crank signal while cranking..... ?    Could you please advise as to what we can try next we are at a loss?????? HELP!
Submitted: 8 years ago.
Category: Dodge
Expert:  Amedee replied 8 years ago.
Hello!

We must be absolutely sure we have a good waveform from both cam and crank sensor for the computer to ground the asd relay circuit. IF the wiring and sensors are good, we can then move onto the asd relay circuit. We must make sure the computer is grounding this relay to power up the injectors etc.
Customer: replied 8 years ago.

ALREADY STARTED THIS PROCEDURE HAS THE PRINTED OUT GRAPH FROM ALL DATA AND IS IN THE PROCESS OF CHECKING THIS BUT SO FAR NO GO.

Expert:  Amedee replied 8 years ago.
And is the computer grounding the asd relay?
Expert:  Amedee replied 8 years ago.
still there?