2006 low hours JCB 3cx loader back hole....I was driving

Customer Question

2006 low hours JCB 3cx loader back hole....I was driving machine down the road..no significant load...and the machine quit just as if I had turned the key off. I waited several hours and tried to start....did not fire at all. Fuel level about 1/3 full. Machine was not hot when it quit.
Submitted: 11 months ago.
Category: Construction and Road Equipment
Expert:  Curtis B. replied 11 months ago.

Check for battery voltage at the fuel shutoff solenoid on the injection pump. Key needs to be on! If it has voltage, the solenoid may have failed, and fuel is not being turned on. If no voltage, check fuses and wires to the solenoid.