i have a ge model zgu650em1bg cook top i bought it used the

Customer Question

i have a ge model zgu650em1bg cook top i bought it used the flames come out realy low they wont even boil water what could be the problem
Submitted: 6 years ago.
Category: Appliance
Expert:  Mike replied 6 years ago.
Does this happen with all the burners?
Customer: replied 6 years ago.

yes

 

Expert:  Mike replied 6 years ago.
Ok since the problem is with all the burners the problem is likely the pressure regulator. Click HERE to order a replacement part. If you have any questions please feel free to ask. Mike

Edited by Mr Fixit on 7/1/2010 at 2:16 PM EST
Customer: replied 6 years ago.

i just bought the that part and put it on

maybe im putting it on back words the arrow goes in the direction of gas flow right

 

Expert:  Mike replied 6 years ago.
Yes correct it goes in the direction of the flow.
Customer: replied 6 years ago.
ok thats the way i put it on and still low flame
Expert:  Mike replied 6 years ago.
Thats odd, I don't see anything else on this model that would effect all the burners. Did you have any work done on the gas supply? Any work done in the kitchen? Is this a new stove top?
Customer: replied 6 years ago.

its a used cook top could it be set up for lp not natural gas ? and if so what do i change

 

Expert:  Mike replied 6 years ago.
It's very possible it's set up for ng or lp...in this case you would need to replace the orifices to the burners. Click HERE to order replacement parts for this unit. Mike