I have an Amana side by side. The freezer seems to be working fine but temp on the other side is 50 degrees.
-Could you explain your situation a little more?We Need the complete model number.Also is there any frost or ice on the freezer walls?
It's an Amana Temp Assure, and I think the model # XXXXX XXXXX There is some ice forming at the top of the freezer near the ice maker
0oI.can40042.1411648495
Hi Ya jobless,A refrigerator or freezer that is cooling, but cooling poorly, may have a problem in one of several areas:Evaporator coilsCondenserPoor cooling is often the result of a heavy frost build-up on the evaporator coils or a condenser that is clogged with dust, lint, and dirt.Evaporator coilsPoor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets.The refrigerator is supposed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited.Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: * The defrost timer * The defrost thermostat (also called the bi-metal switch) * The defrost heaterIf it still does not cool properly, there may be a problem with the refrigerant level or the compressor. You may need to consult with a qualified appliance repair technician to further diagnose the problemCondenserSelf-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator.
I can't see any of the parts you've suggested from the front or the rear. The dust/lint has been cleaned off several days ago BEFORE I had the problem. This refrigerator seems to be sealed in the back. as I see no components that are frosted.
JoblessThe evaporator coils or a condenser that is clogged with dust, lint, and dirt.are usually under the fridge and behind the removable front grill at the bottom front.You need a refrigerater brush to reach in and clean it out.You can't see these coils without removing a panel on the inside of your freezer. There are a few screws you remove inside the freezer to remove the panel walls and this exposes the evaporator coils which will be iced up.A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezerI.can40042.1546660069
Home Appliance Technician
10 Years of experience installing and repairing appliances